Consumables and Spare Parts
There are only two main consumables for the APC-2 Particle counter, sample cups and “O” ring seals for the in-line filter.
- Sample cups can be purchased by the case from CINRG's e-commerce partner, Lubrigard: https://www.lubrigard.com/oil-sampling/oil-analysis-equipment/1oz-Test-Cup-case-of-5000/3051//3051/. The sample cups are available from Oakridge Products and the product code is MC79. The cups are supplied in a case of 5000 cups or if you will be needing a lot of them a skid of 50 cases. See http://oakridgeproducts.com/medical-products/medicine-cups/1-oz-medicine-cup/
- 1 x [CS-VORIF-50] (pack of 50 seals) available from CINRG. The seals are available from McMaster Carr and the product code is 6540K165. See - https://www.mcmaster.com/#catalog/122/3541/=14smwgu
As far as spare parts are concerned there are a few strategic spares supplied with the system which include:-
- 1 x [CS-234-402] Spare valve for Gilson 402 syringe pump.
- 1 x [CS-S25] Spare 25ml syringe for 215 (can be used on either the 215 liquid handler or the 402).
- 1 x [CS-MCB2] Spare dual drive PC board for 402 syringe pump.
- 1 x [CS-GPM-4150] Spare in-line filter. See http://www3.towerhobbies.com/cgi-bin/wti0095p?FVPROFIL=&FVSEARCH=GPMQ4150.
- 1 x [CS-T1418-1] ¼” OD and 1/8” ID Viton Tubing. See - https://www.mcmaster.com/#catalog/122/134/=14sn2q4.
- 1 x [CS-TCIF-20] pack of 20 Tubing clamps See - https://www.mcmaster.com/#catalog/122/308/=14sn2av.
- 1 x blue/ yellow peristaltic pump tube. See - https://www.mcmaster.com/#catalog/122/134/=14sn2q4
Items 1 to 3 are all available from Gilson and the CINRG part number is provided if you wish to purchase directly from CINRG. Items 4,5,6 and 7 could possibly be considered consumables but usage is very low. Item 4 is just an in-line filter for liquid fuel powered RC models and is essentially a 200µm filter. It is only needed if the screen in the instrument’s unit gets damaged (or lost). Items 5 and 6 are sourced from McMaster Carr while item 7 will probably be available through your ICP consumables supplier failing which, the tubes can be purchased from Cole Palmer.
Did you find this article useful?
Related Articles
-
Instrument Errors – Drive Board on 402 Unit
Issue: 402 Unit does not work. You may experience an intermittent green light, and/or intermittent fan movement. Generally this is a failed power tra...
-
Instrument Errors - Baumer Level Sensor Incorrect Readings
Issue: Odd height check readings from the Baumer sensor using the height disk or incorrect solvent dilutions. Check to see if there is any oil buildu...
-
Instrument Errors - Particle Counter Reports Zero Counts
When the particle counter reports zero counts, it normally means that the LDS sensor is dirty but it will also give zero counts if the sampling syring...
-
Sensor Calibration - Materials & Procedure
The CINRG CS-APC-2 can be calibrated on-site by a laboratory technician with the correct hardware and standards in place by following the calibration ...